print logo
KNOWLEDGE BASE

How to change from single outlet to double in dual line dividers?

16 September 2019

Modular dual line dividers provide the possibility of creating a large number of configurations in such a few steps and based on the application requirements

 

The Dual Line system have beendesigned for lubrication with grease of many points on large scale industrialmachinery that operate in difficult operating conditions. These systems can beeasily modified and expanded, thanks to the modularity of the dosing devicesthat can be changed quickly and without working on the pipes.
Specifically, the modular dosing devices fordouble line lubrication systems are composed of a modular base and a dosingvalve. The adjustable flow valves have adjustment turrets with methacrylatehood and O-Ring.

How to change from single outlet to double outlet ?

Modular dual line dividers provide the possibility of creating a large number of configurations in such afew steps and based on the application requirements.

Following are the steps to change from theconfiguration with two outputs to that with one output:

1.  Remove the cap from the output

2. Remove the element from the base and positionit upside down

3. Leave the large central O-Ring and insert thetwo smaller central O-Rings inside it making sure not to damage them

4. Reposition the element on the base andtighten the screws 

5. Connect the new line


 


These steps demonstrate the ease of modifyingthe double line modular dosing devices as needed.

 